WINDA STUDIO

一个选题,多种风格

Winda 的讲解影片,从腐蚀讲起。每个选题有一份附出处的脚本,每种风格是一种画法。每个选题先用几种风格做成网页版,再从中选出讲得最清楚的一种风格做成影片。

1风格

影片可用的 8 种画法

FIG. 01 · CORROSION UNDER INSULATION (CUI)WINDA BEACON · LIBRARYcladdinginsulationsteel wallbore126 o'clockA–A1 WATER INrain · deluge · condensation2 LOW POINTSit runs down and gathers3 HELDthe insulation keeps it wet4 HEATmetal temperature, °C5 FOUNDscreening through insulationSOURCESraindeluge, sprinklerscooling towerscondensationWAYS INfailed joint sealantdamaged claddingnot refitted after workunderside of horizontal runselbowsvessel basespipe supportsnozzles, drain legsoften at 6 o'clockSOAKS UP EASILYmineral woolfibreglasscalcium silicateTAKES UP LESSfoam glassperliteHSE 2011 30–120Cao 2022* 50–175overlap 50–120050100150200* citing NACE SP0198, API RP 583≈0.5 mm/y at 80 °C (HSE, US data)windowsas good as where you cutpulsed eddy currentremaining wall, averagedguided wavelosses from ~10 % of sectionradiographyimages the wallinfraredwet insulation, not corrosionneutron backscatterwet insulation, ~300 m a dayOne source flags thirty to a hundred and twenty degrees Celsius;Source: HSE SPC/TECH/GEN/18 (2011) · Cao et al., Metals 12(4) 561 (2022)
Next-Token Flow

暗室里的解剖图:只用一种强调色,主体画成技术图,编号面板按阶段逐一点亮。

风格 01 · 1 部影片 · 5 套主题色 · 支持浅色模式
Corrosion under insulation: the drawing sheet, as a film1122334455667788AABBCCDDEEFFAACLADDINGINSULATIONSTEELBORE4METAL TEMPERATURE: SEE GRAPH 11325LONGITUDINAL SECTION12 O'CLOCK6 O'CLOCKB236SECTION A–At NOM.t REM.STEEL WALL5WALL LOSS, HIDDEN2WATER AGAINST STEEL3INSULATION, WETCLADDINGDETAIL BSCALE 4 : 1GRAPH 1CUI RISK RANGES BY METAL TEMPERATUREHSE 2011 · CAO ET AL. 2022HSE 2011MOST CRITICALCAO 2022*RISKIESTWHERE THESOURCES STANDLOWER,NOT ZEROSOURCESDIFFERBOTH FLAG ITPEAK RISKSOURCESDIFFERLOWERWHILE HOT050100150200METAL TEMPERATURE, °C* CAO ET AL. 2022, CITING NACE SP0198 AND API RP 583. RANGES ARE FROM THE TWO DOCUMENTS NAMED,NOT THE TEXT OF A PAID STANDARD; ENGINEERING DECISIONS NEED THE CURRENT EDITION OF API RP 583.REVISIONSREVDESCRIPTIONDATEBY0FIRST ISSUE, FROM THE LIBRARY PAGE OF 2026-10-252026-10-26BLNOTES1WATER INHSE 2011 · CAO ET AL. 2022FROM RAIN, COOLING TOWERS, SPRINKLER AND DELUGE SYSTEMS, ORCONDENSATION. IT GETS IN THROUGH BADLY DESIGNED OR FITTEDCLADDING, FAILED JOINT SEALANT, MECHANICAL DAMAGE, ORCLADDING NOT REFITTED AFTER MAINTENANCE.2LOW POINTSHSE 2011 · CAO ET AL. 2022IT GATHERS ON THE UNDERSIDE OF HORIZONTAL RUNS AND ELBOWS, ATVESSEL BASES, PIPE SUPPORTS, NOZZLE CONNECTIONS AND DRAINLEGS. DAMAGE IS OFTEN FOUND AT THE 6 O'CLOCK POSITION.3HELDHSE 2011INSULATION LEAVES A SPACE AGAINST THE METAL WHERE WATER CANSIT WITH AIR. MINERAL WOOL, FIBREGLASS AND CALCIUM SILICATESOAK UP WATER EASILY; FOAM GLASS AND PERLITE TAKE UP LESS.WINDABEACON · LIBRARYTITLECORROSION UNDER INSULATION (CUI)INSULATED HORIZONTAL PIPE: SECTIONS, DETAIL, RISK RANGESREADbeacon.winda.ai/library/corrosion-under-insulationCREDITMADE WITH AI TOOLS. CHECKED BY JUN ZHONG AS EDITOR.DRAWNBEACON LIBRARYCHECKEDJ. ZHONG, EDITORDATE2026-10-26DWG NO.WB-LIB-CUI-001REV0SCALENTSSHEET1 OF 1PROJECTIONWATER, HELD AGAINST THE STEELANODEIRON LEAVES THE METALELECTRONS, THROUGH THE WALLCATHODEOXYGEN AND WATERCONSUME THEMSTEP5ZONEE2where oxygen and water consume them.SOURCEHSE SPC/TECH/GEN/18 (2011) · PHMSA, pipeline corrosion (2008)
工程图纸

制图胶片上的工程图:按真实笔宽画的石墨线条,一种红铅笔强调色,配引线编号、注释、图层与标题栏。

风格 02 · 1 部影片 · 1 套主题色
三维剖切

安静影棚里的三维剖切模型:在 Blender 中建出真实分层,在浏览器里逐层揭开、转动,只用一种信号橙标出正在发生的事。

风格 03 · 1 部影片 · 1 套主题色
BEACON LIBRARY · EXPLAINERCORROSION UNDER INSULATIONSTEP 4 OF 7That is all steel needsWaterSteel wallWet insulationINSET · THE WET STEEL SURFACE, MAGNIFIEDAnodeIron leaves the metaland gives up electronsCathodeOxygen and waterconsume the electronsElectrons travel through the wallwhere oxygen and water consume them.Sources: HSE SPC/TECH/GEN/18 (2011); PHMSA, pipeline corrosion (2008)
报刊图解

暖色纸面上的报刊图解:端正的衬线字体,一种批注强调色,示意图随阅读变化,图表附出处。

风格 04 · 1 部影片 · 1 套主题色
STEEL · PIPE WALLWATER FILM · ELECTROLYTEINSULATION · WETANODEIRON LEAVES THE METALAND GIVES UP ELECTRONSLOCATOR6 O'CLOCKFOUR PARTS, PRESENT TOGETHERANODEiron leaves the metalMETALLIC PATHthe pipe wallCATHODEelectrons consumedELECTROLYTEthe water filmKEYIron ion (+)ElectronDissolved oxygenWaterCorrosion productAN EXPLAINER FROM THE BEACON LIBRARYCorrosionunder insulationWATER HELD AGAINST STEEL · OUT OF SIGHTCUICorrosionunder insulationWINDA BEACON · LIBRARYPIPEINSULATIONSURFACEVIEWSTEEL SURFACE · 6 O'CLOCKWALL LOSSCELLHELDLOW POINTWATER INSCALE · WATER FILM, FULLILLUSTRATIVE, NOT TO SCALENARRATION05 / 10 · THE CELLThey travel through the wall to a cathode,SOURCE · HSE SPC/TECH/GEN/18 (2011) · PHMSA, pipeline corrosion (2008)
微观

暗色底上的实验仪器读数:从管道一路放大到钢材表面,再用两种信号色实时演示腐蚀机理。

风格 05 · 1 部影片 · 1 套主题色
等轴测

以 30° 等轴测画出的整个工艺装置:单一光源,每种材料三个明暗面,线条利落,只用水蓝与朱红两种信号色。

风格 06 · 1 部影片 · 1 套主题色
系列风格

系列的统一风格:统一的画框、字幕、片头与片尾,各段落换用最能讲清那部分的风格。

风格 07 · 1 部影片 · 1 套主题色
立体习题册

阳光下书桌上的一本会动的习题册:页面上的铅笔草图长成玩具感的立体模型,一张行李牌跟着一滴水走,镜头一路推到它发生的尺度。

风格 08 · 1 部影片 · 1 套主题色

2选题

影片讲解的内容,均出自已发布的 Beacon Library 页面

3网页版

选题 × 风格的交互网页;先在这里比较各风格,再制作影片

4影片

选题 × 风格;打开即可播放、拖动进度、切换主题色

FIG. 01 · CORROSION UNDER INSULATION (CUI)WINDA BEACON · LIBRARYcladdinginsulationsteel wallbore126 o'clockA–A1 WATER INrain · deluge · condensation2 LOW POINTSit runs down and gathers3 HELDthe insulation keeps it wet4 HEATmetal temperature, °C5 FOUNDscreening through insulationSOURCESraindeluge, sprinklerscooling towerscondensationWAYS INfailed joint sealantdamaged claddingnot refitted after workunderside of horizontal runselbowsvessel basespipe supportsnozzles, drain legsoften at 6 o'clockSOAKS UP EASILYmineral woolfibreglasscalcium silicateTAKES UP LESSfoam glassperliteHSE 2011 30–120Cao 2022* 50–175overlap 50–120050100150200* citing NACE SP0198, API RP 583≈0.5 mm/y at 80 °C (HSE, US data)windowsas good as where you cutpulsed eddy currentremaining wall, averagedguided wavelosses from ~10 % of sectionradiographyimages the wallinfraredwet insulation, not corrosionneutron backscatterwet insulation, ~300 m a dayOne source flags thirty to a hundred and twenty degrees Celsius;Source: HSE SPC/TECH/GEN/18 (2011) · Cao et al., Metals 12(4) 561 (2022)
保温层下腐蚀(CUI)是什么?
Next-Token Flow · 111 秒 · 1920×1080 · 30 fps
Corrosion under insulation: the drawing sheet, as a film1122334455667788AABBCCDDEEFFAACLADDINGINSULATIONSTEELBORE4METAL TEMPERATURE: SEE GRAPH 11325LONGITUDINAL SECTION12 O'CLOCK6 O'CLOCKB236SECTION A–At NOM.t REM.STEEL WALL5WALL LOSS, HIDDEN2WATER AGAINST STEEL3INSULATION, WETCLADDINGDETAIL BSCALE 4 : 1GRAPH 1CUI RISK RANGES BY METAL TEMPERATUREHSE 2011 · CAO ET AL. 2022HSE 2011MOST CRITICALCAO 2022*RISKIESTWHERE THESOURCES STANDLOWER,NOT ZEROSOURCESDIFFERBOTH FLAG ITPEAK RISKSOURCESDIFFERLOWERWHILE HOT050100150200METAL TEMPERATURE, °C* CAO ET AL. 2022, CITING NACE SP0198 AND API RP 583. RANGES ARE FROM THE TWO DOCUMENTS NAMED,NOT THE TEXT OF A PAID STANDARD; ENGINEERING DECISIONS NEED THE CURRENT EDITION OF API RP 583.REVISIONSREVDESCRIPTIONDATEBY0FIRST ISSUE, FROM THE LIBRARY PAGE OF 2026-10-252026-10-26BLNOTES1WATER INHSE 2011 · CAO ET AL. 2022FROM RAIN, COOLING TOWERS, SPRINKLER AND DELUGE SYSTEMS, ORCONDENSATION. IT GETS IN THROUGH BADLY DESIGNED OR FITTEDCLADDING, FAILED JOINT SEALANT, MECHANICAL DAMAGE, ORCLADDING NOT REFITTED AFTER MAINTENANCE.2LOW POINTSHSE 2011 · CAO ET AL. 2022IT GATHERS ON THE UNDERSIDE OF HORIZONTAL RUNS AND ELBOWS, ATVESSEL BASES, PIPE SUPPORTS, NOZZLE CONNECTIONS AND DRAINLEGS. DAMAGE IS OFTEN FOUND AT THE 6 O'CLOCK POSITION.3HELDHSE 2011INSULATION LEAVES A SPACE AGAINST THE METAL WHERE WATER CANSIT WITH AIR. MINERAL WOOL, FIBREGLASS AND CALCIUM SILICATESOAK UP WATER EASILY; FOAM GLASS AND PERLITE TAKE UP LESS.WINDABEACON · LIBRARYTITLECORROSION UNDER INSULATION (CUI)INSULATED HORIZONTAL PIPE: SECTIONS, DETAIL, RISK RANGESREADbeacon.winda.ai/library/corrosion-under-insulationCREDITMADE WITH AI TOOLS. CHECKED BY JUN ZHONG AS EDITOR.DRAWNBEACON LIBRARYCHECKEDJ. ZHONG, EDITORDATE2026-10-26DWG NO.WB-LIB-CUI-001REV0SCALENTSSHEET1 OF 1PROJECTIONWATER, HELD AGAINST THE STEELANODEIRON LEAVES THE METALELECTRONS, THROUGH THE WALLCATHODEOXYGEN AND WATERCONSUME THEMSTEP5ZONEE2where oxygen and water consume them.SOURCEHSE SPC/TECH/GEN/18 (2011) · PHMSA, pipeline corrosion (2008)
保温层下腐蚀(CUI)是什么?
工程图纸 · 111 秒 · 1920×1080 · 30 fps
保温层下腐蚀(CUI)是什么?
三维剖切 · 111 秒 · 1920×1080 · 30 fps
BEACON LIBRARY · EXPLAINERCORROSION UNDER INSULATIONSTEP 4 OF 7That is all steel needsWaterSteel wallWet insulationINSET · THE WET STEEL SURFACE, MAGNIFIEDAnodeIron leaves the metaland gives up electronsCathodeOxygen and waterconsume the electronsElectrons travel through the wallwhere oxygen and water consume them.Sources: HSE SPC/TECH/GEN/18 (2011); PHMSA, pipeline corrosion (2008)
保温层下腐蚀(CUI)是什么?
报刊图解 · 111 秒 · 1920×1080 · 30 fps
STEEL · PIPE WALLWATER FILM · ELECTROLYTEINSULATION · WETANODEIRON LEAVES THE METALAND GIVES UP ELECTRONSLOCATOR6 O'CLOCKFOUR PARTS, PRESENT TOGETHERANODEiron leaves the metalMETALLIC PATHthe pipe wallCATHODEelectrons consumedELECTROLYTEthe water filmKEYIron ion (+)ElectronDissolved oxygenWaterCorrosion productAN EXPLAINER FROM THE BEACON LIBRARYCorrosionunder insulationWATER HELD AGAINST STEEL · OUT OF SIGHTCUICorrosionunder insulationWINDA BEACON · LIBRARYPIPEINSULATIONSURFACEVIEWSTEEL SURFACE · 6 O'CLOCKWALL LOSSCELLHELDLOW POINTWATER INSCALE · WATER FILM, FULLILLUSTRATIVE, NOT TO SCALENARRATION05 / 10 · THE CELLThey travel through the wall to a cathode,SOURCE · HSE SPC/TECH/GEN/18 (2011) · PHMSA, pipeline corrosion (2008)
保温层下腐蚀(CUI)是什么?
微观 · 111 秒 · 1920×1080 · 30 fps
保温层下腐蚀(CUI)是什么?
等轴测 · 111 秒 · 1920×1080 · 30 fps
保温层下腐蚀(CUI)是什么?
系列风格 · 111 秒 · 1920×1080 · 30 fps
保温层下腐蚀(CUI)是什么?
立体习题册 · 111 秒 · 1920×1080 · 30 fps